20 Şubat OTOMATİK SİSTEM KALORİFER KAZANI KULLANMA KILAVUZU

OTOMATİK SİSTEM KALORİFER KAZANI KULLANMA KILAVUZU

OTOMATiK SiSTEM KALORiFER KAZANI KULLANMA KILAVUZU
KAZAN PANOSUNDA BULUNAN AKSESURLAR
1- AÇMA KAPAMA ANAHTARı
GÖREVi: SiRKÜLASYON POMPASı VE KÖMÜR SÜRÜCÜSÜNE KUMANDA EDER.
2 - BUTON
GÖREVi: KAZANIN iLK YAKMA ANıNDA HAZNEYE KÖMÜR ALMASıNı SAGLARYETERiNCE KÖMÜR ALlNINCA
BUTON BıRAKıLIR
3 - TERMOMETRE
GÖREVi: KAZANIN SICAKLIGINI GÖSTERiR
4 - TERMOSTAT
GÖREVi: AYARLANAN sıCAKlıKTA KAZANI STOPA GEçiRiRSıcAKlıK DÜŞÜNCE TEKRAR KAZANI DEVREYE AlıR
5 - FAN AYAR DÜGMESi
GÖREVi: FAN HAVA AYRINI YAPARYAKIT CiNSiNE GÖRE HAVAYI AZALTıR VE ÇOGALTIR
6 - ZAMAN AYAR ROLESi
GÖREVi: KAZANA KÖMÜR SÜRME ZAMANıNı VE SÜRESiNi AYARLARDAKiKA KısMI KÖMÜRÜ ALDıKTAN SONRAKi
DURAKLAMA ZAMANıDıRSANiYE KısMI KÖMÜRÜ HAZNEYE SÜRME ZAMANıDıR
7 - KONDAKTÖR
B-siGORTA
KAZAN BAKIMI- ARlZA SEBEPLERi VE GiDERiLMESi
1 - HELEZON SIKIŞMASI: GiDERLMESi MOTORLA OLAN BAGLANTI SÖKÜLEREK HELEZON ÇıKARılıR
ARIZAYA SEBEP OLAN CiSiM ALINARAK TEKRAR HELEZON YERiNE TAKILlRO ANDA MÜDAHALE YAPILAMIYORSA
PANO ÜZERiNDE BULUNAN KUMANDA ANAHTARı KAPATlLARAK,ÖN KAPAKTAN MANUEL OLARAK KAZAN YAKılıR
GEREKli MÜDAHALE SERViS ELEMANIMIZCA DAHA SONRA YAPılıRBÖYLE BiR ARIZAYA SEBEBiYET VERMEMEK
iÇiN KÖMÜR KOVASINA KÖMÜRÜ DÖKMEDEN ÖNCE KÖMÜRÜ BiR KABA DÖKEREK GEREKli KONTROLÜN
YAPıLMASı GEREKiR
2 - FAN ÜFLEMiYORSA : FAN AYAR DÜGMESi KAPALI OLABiliRVEYA YANMA HAZNESiNiN ALTı KÜL DOLU
OLABiLiRKÜLÜ,YANMA HAZNESiNDEKi DEliKli TASı SÖKEREK BOŞALTıN. (KAT KALORiFERi iÇiN)
MERKEZi SiSTEM KAZANLARDA DEliKli TASIN ALTINDAKı KÜL KOVASININ ÖN KısMıNDA BULUNAN KAPAKTAN KÜLÜ
BOŞALTıNIZ.
3 - KAZANIN YETERiNCE iSi VERMEMESi: KAZAN PETEKLERi ARASI DOLMUŞ OLABiLiR,FAN YETERiNCE
HAVA VERMiYOR OLABiliR VEYA KAZAN HAZNEYE YETERiNCE KÖMÜR ALMıYOR OLABiLiR.BU DURUMDA KAZA NA
YETERiNCE HAVA GiRiŞiNi TEMiN EDiN.PETEKLERi BACA SiL KULLANARAK TEMiZLEYiN.KAZAN YANARKEN KAZANA
YETERiNCE BACA SiL ATIN.YETERiNCE KÖMÜR ALMIYORSA KÖMÜR SÜRME ZAMANıNı VE SÜRESiNi iyi
AYARLAYINIZ.KÖMÜR KALORiSiNE GÖRE BU AYAR DEGiŞKENLiK GÖSTERiRBORULU KAZANLARDA BORULARıN
KROM DOLU OLMADIGINI KONTROL EDEREK,BORU TEMiZliGiNE ÖZEN GÖSTERiN.
4 - KAZAN,AYARLANAN ISIVA GELiNCE STOP ETMivORSA; TERMOSTAT BOZUK OLABiliR
5 - FAN, AVARLANAN ISIVA GELiNCE STOP ETMivORSA; FAN AYAR DÜGMESi BOZUK OLABiliR
6 - SÜREKLi KÖMÜR ÇEKivORSA VEVA ÇEKMivORSA ; KONDAKTÖR ARıZAlı OLABiliR
NOT: KÖMÜRLÜ KAZANLARı KAPALI DEVRE ÇALlŞTIRMAYIN,siSTEM BU ŞEKiLDE

Okuma : 3523